  <post>
    <IP type="integer">0.0.0.0</IP>
    <author-id type="integer">22465</author-id>
    <blog-id type="integer">14263</blog-id>
    <body>   &lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://4.bp.blogspot.com/_WfKuaRVqTzo/SiVvSwcJUpI/AAAAAAAAY14/G3I5zVfCpR0/s1600-h/8.+IMG_6117.JPG"&gt;&lt;img style="cursor: pointer; width: 400px; height: 300px;" src="http://4.bp.blogspot.com/_WfKuaRVqTzo/SiVvSwcJUpI/AAAAAAAAY14/G3I5zVfCpR0/s400/8.+IMG_6117.JPG" alt="" id="BLOGGER_PHOTO_ID_5342798900976243346" border="0"&gt;&lt;/a&gt;
&lt;span style="font-size: 85%;"&gt;Foto: blas&lt;/span&gt;

&lt;ul&gt;&lt;li&gt; &lt;span style="font-size: 180%;"&gt;&lt;a style="font-weight: bold;" dir="ltr" href="http://blas-atletismoyalgoms.blogspot.com/search/label/Ecologistas%20en%20Acci%C3%B3n"&gt;Ecologistas en Acci&#243;n&lt;/a&gt;&lt;/span&gt;&lt;span dir="ltr"&gt;&lt;/span&gt; &lt;/li&gt;&lt;/ul&gt;&lt;span style="font-size: 85%;"&gt;
&lt;/span&gt;

&lt;span style="font-size: 85%;"&gt;EFE&lt;/span&gt;


&lt;p style="text-align: justify;"&gt;Seis estaciones de control de la calidad del aire en Madrid superaron ayer el Umbral de Protecci&#243;n a la Salud -120 microgramos por metro c&#250;bico- del llamado "ozono malo" durante una media de ocho horas, a pesar de que miles de atletas corr&#237;an ayer en diferentes eventos deportivos en la capital.

&lt;div style="text-align: justify;"&gt; &lt;/div&gt;&lt;p style="text-align: justify;"&gt;As&#237; lo ha denunciado Ecologistas en Acci&#243;n, que ha explicado que la pr&#225;ctica deportiva exige "una mayor entrada de aire en los pulmones, del orden de hasta cinco veces m&#225;s que en reposo, por lo que hacer deporte ayer en Madrid pod&#237;a ser perjudicial para la salud".

&lt;div style="text-align: justify;"&gt; &lt;/div&gt;&lt;p style="text-align: justify;"&gt;La ONG ha recordado que ayer Madrid era escenario de un campeonato mundial de triatl&#243;n (nataci&#243;n, bicicleta y carrera a pie de 10 kil&#243;metros) que se celebr&#243; en la Casa de Campo, en donde la estaci&#243;n de calidad del aire super&#243; durante m&#225;s de ocho horas los 120 microgramos por metro c&#250;bico.

&lt;div style="text-align: justify;"&gt; &lt;/div&gt;&lt;p style="text-align: justify;"&gt;Por su parte, en el centro de la capital transcurr&#237;a otra prueba, mucho m&#225;s concurrida (10.000 personas), con un recorrido de m&#225;s de diez kil&#243;metros que pasaba por zonas "poco saludables", como Manuel Becerra.

&lt;div style="text-align: justify;"&gt; &lt;/div&gt;&lt;p style="text-align: justify;"&gt;Las seis estaciones que tuvieron superaciones del Umbral de Protecci&#243;n a la Salud para este contaminante est&#225;n situadas en la Casa de Campo, Manuel Becerra, Vallecas, Arturo Soria, General Ricardos y Urbanizaci&#243;n Embajada.

&lt;div style="text-align: justify;"&gt; &lt;/div&gt;&lt;p style="text-align: justify;"&gt;Los ecologistas han se&#241;alado que el ozono "malo" o troposf&#233;rico act&#250;a sobre el tracto respiratorio produciendo la de oxidaci&#243;n de millones de c&#233;lulas pulmonares, con lo que "la supuesta bondad de la pr&#225;ctica deportiva se convierte en justo lo contrario".

&lt;div style="text-align: justify;"&gt; &lt;/div&gt;&lt;p style="text-align: justify;"&gt;El ozono que ayer afect&#243; a Madrid "procede de forma indirecta de los tubos de escape de los coches", ya que los gases que emiten, sobre todo el di&#243;xido de nitr&#243;geno, reaccionan en condiciones de fuerte insolaci&#243;n, como las de ayer, para generar ozono.

&lt;div style="text-align: justify;"&gt; &lt;/div&gt;&lt;p style="text-align: justify;"&gt;Ecologistas en Acci&#243;n ha criticado que la situaci&#243;n actual se caracteriza por "una clamorosa falta de informaci&#243;n" a la ciudadan&#237;a sobre los niveles y efectos de este gas, as&#237; como de medidas efectivas para evitar que estas situaciones se produzcan, como la limitaci&#243;n del tr&#225;fico.

&lt;div style="text-align: justify;"&gt;&lt;span style="font-size: 85%;"&gt;Fuente: adn.es&lt;/span&gt;

&lt;span style="font-size: 180%;"&gt;&lt;span style="font-weight: bold;"&gt;ENLACES:&lt;/span&gt;&lt;/span&gt;
&lt;/div&gt;&lt;h3 class="post-title entry-title"&gt;&lt;a href="http://blas-atletismoyalgoms.blogspot.com/2009/06/3936-seis-estaciones-de-medicion.html"&gt;Seis estaciones de medici&#243;n superaron ayer Umbral Protecci&#243;n Salud de ozono. Ecologistas en Acci&#243;n, dice que los atletas sufrieron en Madrid.&lt;/a&gt;&lt;/h3&gt; &lt;h3 style="text-align: justify;" class="post-title entry-title"&gt;&lt;a href="http://blas-atletismoyalgoms.blogspot.com/2009/05/3817-botella-justifica-en-una-directiva.html"&gt;3817. Botella justifica en una directiva la supresi&#243;n de medidores de poluci&#243;n. El cambio de ubicaci&#243;n de las estaciones hace perder la hist&#243;ria.&lt;/a&gt;
&lt;/h3&gt;&lt;h3 style="text-align: justify;" class="post-title entry-title"&gt;&lt;a href="http://blas-atletismoyalgoms.blogspot.com/2009/05/3726-solicitan-reunirse-con-el.html"&gt;3726. Solicitan reunirse con el Presidente del Gobierno para fijar el compromiso clim&#225;tico de Espa&#241;a. Coalici&#243;n Clima, la mayor plataforma espa&#241;ola.&lt;/a&gt;&lt;/h3&gt;&lt;h3 style="text-align: justify;" class="post-title entry-title"&gt;&lt;a href="http://blas-atletismoyalgoms.blogspot.com/2009/04/3610-carta-al-alcalde-carrera-hacia-la.html"&gt;3610. CARTA AL ALCALDE. Carrera hacia la insostenibilidad. La capital ignora la lucha contra el cambio clim&#225;tico, seg&#250;n Ecologistas en Acci&#243;n.&lt;/a&gt;&lt;/h3&gt;&lt;h3 style="text-align: justify;" class="post-title entry-title"&gt;&lt;a href="http://blas-atletismoyalgoms.blogspot.com/2008/09/1785-rogativa-san-eolo-una-nueva.html"&gt;1785. Rogativa a San Eolo. Una nueva estrategia de lucha contra la contaminaci&#243;n. Ecologistas en Acci&#243;n ha decidido recurrir al m&#233;todo tradicional...&lt;/a&gt;&lt;/h3&gt;&lt;h3 style="text-align: justify;" class="post-title entry-title"&gt;&lt;a href="http://blas-atletismoyalgoms.blogspot.com/2008/09/1671-madrid-ha-respirado-este-verano.html"&gt;1671. Madrid ha respirado este verano uno de los peores aires de su historia debido a las altas concentraciones de ozono detectadas en las estaciones.&lt;/a&gt;&lt;/h3&gt;</body>
    <closed-comments type="boolean"></closed-comments>
    <closed-trackbacks type="boolean"></closed-trackbacks>
    <comments-count type="integer">0</comments-count>
    <created-at type="datetime">2009-06-04T12:10:21Z</created-at>
    <date type="datetime">2009-06-04T12:12:00Z</date>
    <id type="integer">332321</id>
    <last-comment-date type="datetime"></last-comment-date>
    <myfile-id type="integer"></myfile-id>
    <nicetitle>seis-estaciones-medicion-superaron-ayer-umbral-proteccion</nicetitle>
    <published-at type="datetime">2009-06-04T12:12:06Z</published-at>
    <site-id type="integer">1</site-id>
    <status type="integer">1</status>
    <title>Seis estaciones de medici&#243;n superaron ayer Umbral Protecci&#243;n Salud de ozono. Ecologistas en Acci&#243;n, dice que los atletas sufrieron en Madrid.</title>
    <updated-at type="datetime">2009-06-04T12:12:06Z</updated-at>
  </post>
  <post>
    <IP type="integer">0.0.0.0</IP>
    <author-id type="integer">1874</author-id>
    <blog-id type="integer">1930</blog-id>
    <body>&lt;h1&gt;Verificacion de errores en equipos electricos&lt;/h1&gt;&lt;strong&gt;Sinopsis&lt;/strong&gt;
La verificaci&#243;n de fallos es un procedimiento utilizado para confirmar que un &lt;a href="http://www.amperis.com/productos/analizadores-redes/"&gt;equipo de seguridad el&#233;ctrica&lt;/a&gt; funciona correctamente y detectar&#225; los fallos en dicho dispositivo.

&lt;h3&gt;Mec&#225;nica en la naturaleza&lt;/h3&gt;Muchos de los medidores de seguridad disponibles en el mercado eran de la edad anal&#243;gica.

Hoy en d&#237;a los medidores de seguridad son controlados por microprocesador de alta tecnolog&#237;a y software impulsado por circuitos que permiten la verificaci&#243;n con el fin de ser incorporada en el propio instrumento. Estos no s&#243;lo eliminan un equipo mec&#225;nico extra sino que ahorran costos, adem&#225;s las pruebas son m&#225;s f&#225;ciles y m&#225;s seguras puesto que no hay nada externo para conectar. El sistema de verificaci&#243;n interna determina si el probador detecta un fallo.

Diversas agencias de seguridad han exigido a los fabricantes realizar estas pruebas, asegurando que los productos funcionen correctamente. Y si bien es posible que un componente cause un mal funcionamiento del instrumento, hay otras condiciones que pueden causar resultados inexactos en ensayos de seguridad el&#233;ctrica.

&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;1. &lt;/strong&gt;Si la alta Tensi&#243;n o la devoluci&#243;n es abierta entonces es posible que el instrumento no detecte errores a causa de esta condici&#243;n de circuito abierto. Aunque recientes instrumentos modernos usan tecnolog&#237;as como "Ajustes Bajo L&#237;mite" y "Carga DC" la detecci&#243;n ayuda a eliminar este problema. La verificaci&#243;n puede ayudar a asegurar que estos par&#225;metros se establecen correctamente.&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;2.&lt;/strong&gt; Muchas pruebas de seguridad se realizan a trav&#233;s de diversos tipos de acople. Esto tambi&#233;n crea una condici&#243;n de circuito abierto que puede ser detectado con bajos l&#237;mites de carga y ajustes DC-LO. &lt;/li&gt;
&lt;li&gt;&lt;strong&gt;3.&lt;/strong&gt; Aunque los instrumentos m&#225;s recientes son m&#225;s a prueba de manipulaciones, siempre es posible que alguien con el acceso a los men&#250;s de configuraci&#243;n puede haber cambiado o desconfigurar los par&#225;metros de detecci&#243;n de sistemas. La verificaci&#243;n puede ayudar a poner a prueba todos los modos de las pruebas de seguridad el&#233;ctrica.&lt;/li&gt;
&lt;/ul&gt;&lt;h3&gt;Requisitos de la Agencia Europea de Seguridad&lt;/h3&gt;La mayor parte de las directrices de la Agencia Europea de Seguridad permiten que el personal que ha sido correctamente formado en el uso de pruebas de seguridad, pueda llevar a cabo la verificaci&#243;n de fallos de los instrumentos. Pero &#191;Con qu&#233; frecuencia se deben realizar estas pruebas de verificaci&#243;n?. Depende de cada organismo. Algunos organismos pueden exigir que esta prueba se realice varias veces al d&#237;a. Tambi&#233;n es muy com&#250;n realizar puruebas de verificaci&#243;n al comienzo de cada cambio de turno. Sin embargo, otros organismos s&#243;lo requieren la verificaci&#243;n al comienzo o al final de cada d&#237;a.

Por supuesto, el fabricante es el primetro en conocer las directrices de sus respectivos organismos de seguridad.

Se recomienda que la verificaci&#243;n se realice en cada cambio de turno, ya que es, por lo general un tiempo conveniente para llevar a cabo la prueba y se garantiza el proceso de verificaci&#243;n a un nuevo operador.

Aunque la mayor&#237;a de los organismos de seguridad establecen directrices para llevar a cabo la frecuencia de las pruebas verificaci&#243;n, ninguno hace recomendaciones para la forma exacta en que la prueba debe ser realizada. Esto ha dado lugar a cierta confusi&#243;n y varios m&#233;todos diferentes se han recomendado por los fabricantes de instrumentos de ensayo de seguridad el&#233;ctrica.

&lt;h3&gt;M&#233;todos de Verificaci&#243;n de ensayo Comunes&lt;/h3&gt;&lt;strong&gt;M&#233;todos de resistencia&lt;/strong&gt; - Resistencias fijas se pueden utilizar para verificar fallos en instrumentos. Muchos fabricantes proporcionan cajas con varios valores comunes de resistencia incorporados. El operador debe seleccionar la resistencia correcta y conectar los conductores de prueba a trav&#233;s de la carga resistiva. La resistencia seleccionada debe ser un valor que permita suficiente flujo de corriente en una prueba de tensi&#243;n superior a la del instrumento de detecci&#243;n de fallos en circuitos el&#233;ctricos.

La tensi&#243;n de ensayo puede ser puesta al instante o aumentarla gradualmente al nivel seleccionado. Si la detecci&#243;n del fallo de los circuitos est&#225; funcionando correctamente el instrumento debe indicar un error antes de que la prueba de tensi&#243;n sea alcanzada. Un inconveniente de este m&#233;todo es que no permite variaciones de un producto a otro, por lo que se hace necesario seleccionar y utilizar distintos tipos de valores de resistencia o seleccionar una que genere suficiente corriente para simular el error en todos los dispositivos bajo prueba (DUT's, Device Under Test)

&lt;strong&gt;M&#233;todo del Switch Externo&lt;/strong&gt; - Otro m&#233;todo muy sencillo para realizar la verificaci&#243;n de la seguridad es simplemente mediante la conexi&#243;n de los conductores de prueba juntos para crear un corto circuito. Si el instrumento est&#225; funcionando correctamente deber&#237;a notarse un excesivo flujo de corriente e indicar un fallo.

Si el instrumento indica error durante la detecci&#243;n del fallo significar&#225; que el sistema de verificaci&#243;n del Hipot ha sido verificado.

 Este mismo procedimiento se puede utilizar para realizar la verificaci&#243;n de fallos IR.

El cortocircuito ser&#225; causado por la baja resistencia, que deber&#225; ser tomado como un error del instrumento.

El comportamiento de la continuidad y la comprobaci&#243;n de la conexi&#243;n a tierra es similar, salvo que ahora, una conexi&#243;n de corto se considera adecuada. Recuerde que estas pruebas buscan la continuidad pero una condici&#243;n abierta ahora representa error. Para simular continuidad y la comprobaci&#243;n de la conexi&#243;n de &lt;a href="http://www.amperis.com/productos/telurometros/"&gt;puesta a tierra&lt;/a&gt; el conductor de prueba debe quedar abierto, mientras que la prueba se ejecuta para simular un DUT conexi&#243;n a tierra.

Aunque este sistema de trabajo dispositivo externo para realizar la prueba de verificaci&#243;n.



&lt;img style="margin: 0pt 0.5em 0pt 0pt; float: left;" src="http://www.amperis.com/images/megohmetros/megohmetro-mic-5000.jpg" alt="Meg&#243;hmetro Medidor aislamiento MIC-5000" width="245" height="280"&gt;
El medidor de aislamiento modelo MIC-5000 se emplea principalmente en &lt;a href="http://www.amperis.com/productos/megohmetros/" title="Equipos para pruebas de resistencia de aislamiento, Meg&#243;hmetros"&gt;pruebas de resistencia de aislamiento&lt;/a&gt; en cables de potencia, motores el&#233;ctricos, transformadores, y otros equipos relacionados con la energ&#237;a el&#233;ctrica.
El equipo realiza la medida de tensiones continuas y alternas as&#237; como medida de resistencias bajas con tensiones bajas. Los terminales del equipo est&#225;n protegidos frente a sobretensiones y cumple la norma &lt;a class="glos" title="Descripci&#243;n del t&#233;rmino en el Glosario" href="http://www.amperis.com/recursos/glosario/#IEC61557"&gt;IEC 61557&lt;/a&gt;.

&lt;span style="font-weight: bold;"&gt;Sepa m&#225;s sobre este fant&#225;stico equipo de &lt;/span&gt;&lt;a style="font-weight: bold;" href="http://www.amperis.com/productos/megohmetros/mic-5000/"&gt;medici&#243;n de aislamiento&lt;/a&gt;&lt;span style="font-weight: bold;"&gt; en la web de Amperis - &lt;/span&gt;&lt;a style="font-weight: bold;" href="http://www.amperis.com/"&gt;Instrumentos de medicion&lt;/a&gt;</body>
    <closed-comments type="boolean"></closed-comments>
    <closed-trackbacks type="boolean"></closed-trackbacks>
    <comments-count type="integer">2</comments-count>
    <created-at type="datetime">2008-10-03T07:17:00Z</created-at>
    <date type="datetime">2008-10-03T07:13:00Z</date>
    <id type="integer">208928</id>
    <last-comment-date type="datetime">2009-06-02T21:32:41Z</last-comment-date>
    <myfile-id type="integer"></myfile-id>
    <nicetitle>verificacion-errores-equipos-electricos</nicetitle>
    <published-at type="datetime">2008-10-03T07:16:59Z</published-at>
    <site-id type="integer">1</site-id>
    <status type="integer">1</status>
    <title>Verificacion de errores en equipos electricos</title>
    <updated-at type="datetime">2009-06-02T21:32:41Z</updated-at>
  </post>
  <post>
    <IP type="integer">0.0.0.0</IP>
    <author-id type="integer">1874</author-id>
    <blog-id type="integer">1930</blog-id>
    <body>&lt;h2&gt;Micr&#243;hmetros - Acerca de la corriente de prueba&lt;/h2&gt;
El valor de una resistencia de contacto primario (la resistencia entre dos terminales de cualquier polo de un interruptor) normalmente se mide antes de que se ponga el interruptor de circuito en servicio por primera vez y durante las inspecciones de mantenimiento. La resistencia de contacto es un valor que se especifica como una red para todas las clases de interruptores de circuito: de acuerdo con la IEC 56 (ahora IEC62271-100), este valor de resistencia se debe medir usando una corriente de prueba de entre 50A y el valor nominal de la corriente del interruptor. De acuerdo con la ANSI C 37.09, la corriente de prueba inferior es de 100A. Otras normas nacionales e internacionales especifican regulaciones similares.



Por lo regular, el fabricante define el valor de la corriente de prueba. La mayor parte de los fabricantes (ABB, Alstom, etc.) especifican la corriente de prueba en 200A. Algunos proveedores del servicio de energ&#237;a tienen sus propias regulaciones (Vattenfall_Suecia mide la resistencia de contacto para los interruptores y desconecta los interruptores en 300A). Otros usan una corriente de prueba de 500A o 600A, en tanto que algunos no pasan de 100A.
Opinamos que el valor de la corriente de prueba de 300A (a menudo, inclusive de 200A) es suficiente para una medici&#243;n correcta y confiable.



Si hay alguna duda sobre la precisi&#243;n de la medici&#243;n o la condici&#243;n de los contactos, se puede repetir la medici&#243;n usando el valor de corriente m&#225;s alto. Nuestra experiencia demuestra el mejor resultado usando el modo CONT - medici&#243;n de corriente continua con 200A a 300A con una duraci&#243;n de 50 segundos.

Las corrientes de prueba m&#225;s altas aumentan la precisi&#243;n, pero la corriente de prueba con m&#225;s de 300A ofrece una mejora insignificante en la precisi&#243;n. Las corrientes m&#225;s altas requieren cables m&#225;s grandes, que son pesados y hacen que el procedimiento de medici&#243;n de la resistencia sea problem&#225;tico y complicado, sin ninguna mejora considerable en el resultado.



&lt;strong&gt;&lt;em&gt;Conclusi&#243;n:&lt;/em&gt;&lt;/strong&gt;


 &lt;strong&gt;Recomendamos la corriente de prueba de 300A&lt;/strong&gt;. Para la mayor&#237;a de las situaciones, la corriente de prueba de 200A es suficiente. En caso de dudas, repita la prueba usando el modo Cont con una medici&#243;n con mayor duraci&#243;n con corrientes de 300A o 200A.
Se recomienda usar 400A o 500A para situaciones en que se espera que la resistencia de contacto medida sea de menos de 20&#181;O.


&lt;h2&gt;&lt;a href="http://www.amperis.com/productos/microhmetros/" title="http://www.amperis.com/productos/microhmetros/" id="link_0"&gt;Microhmetro&lt;/a&gt;  - Declaraci&#243;n sobre la precisi&#243;n&lt;/h2&gt;
La precisi&#243;n de los &lt;a href="http://www.amperis.com/productos/microhmetros/" title="http://www.amperis.com/productos/microhmetros/" id="link_1"&gt;Microhmetros&lt;/a&gt;  se define como &#177;(0,25% rdg + 0,25% FS) siempre que se satisfagan las dos condiciones siguientes:


&lt;ul&gt;&lt;li&gt;que la corriente de la medici&#243;n sea de por lo menos 100A &lt;/li&gt;
&lt;li&gt;que el rango de la medici&#243;n est&#233; entre 100&#181;O y 20mO&lt;/li&gt;&lt;/ul&gt;
Si la corriente es de menos de 100A, se puede establecer la precisi&#243;n siguiendo la tabla siguiente:


&lt;table cellpadding="0" width="50%"&gt;
  &lt;tbody&gt;&lt;tr&gt;
    &lt;td&gt;&lt;strong&gt;Corriente de Prueba&lt;/strong&gt;&lt;/td&gt;
    &lt;td&gt;&lt;strong&gt;Error&lt;/strong&gt;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;50 A&lt;/td&gt;
    &lt;td&gt;0,25%+1&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;20 A&lt;/td&gt;
    &lt;td&gt;0,5%+2&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;10 A&lt;/td&gt;
    &lt;td&gt;1%+5&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
&lt;/tbody&gt;&lt;/table&gt;

No se recomienda la medici&#243;n de resistencias por debajo de los 100&#181;O con corriente de menos de 100A.


En el caso de una resistencia de entre 20&#181;O y 100&#181;O se define la precisi&#243;n como sigue:


&lt;table cellpadding="0" width="50%"&gt;
  &lt;tbody&gt;&lt;tr&gt;
    &lt;td&gt;&lt;strong&gt;Corriente de Prueba&lt;/strong&gt;&lt;/td&gt;
    &lt;td&gt;&lt;strong&gt;Error&lt;/strong&gt;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;600 A&lt;/td&gt;
    &lt;td&gt;0,25%+0,5&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;500 A&lt;/td&gt;
    &lt;td&gt;0,25%+0,6&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;400 A&lt;/td&gt;
    &lt;td&gt;0,25%+0,7&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;300 A&lt;/td&gt;
    &lt;td&gt;0,25%+0,8&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;200 A&lt;/td&gt;
    &lt;td&gt;0,25%+0,9&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;100 A&lt;/td&gt;
    &lt;td&gt;0,25%+1,0&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
&lt;/tbody&gt;&lt;/table&gt;
Para un esp&#233;cimen con resistencia sobre 20mOhm, se define la precisi&#243;n usando la tabla:



&lt;table cellpadding="0" width="50%"&gt;
  &lt;tbody&gt;&lt;tr&gt;
    &lt;td&gt;&lt;strong&gt;Corriente de    Prueba&lt;/strong&gt;&lt;/td&gt;
    &lt;td&gt;&lt;strong&gt;Error&lt;/strong&gt;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;50 A&lt;/td&gt;
    &lt;td&gt;0,25%+1&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;20 A&lt;/td&gt;
    &lt;td&gt;0,5%+2&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;10 A&lt;/td&gt;
    &lt;td&gt;1%+5&#181;&#937;&lt;/td&gt;
  &lt;/tr&gt;
&lt;/tbody&gt;&lt;/table&gt;
Si requiere una mayor precisi&#243;n, necesita:


&lt;ul&gt;&lt;li&gt;verificar la calibraci&#243;n del instrumento usando la Derivaci&#243;n de Prueba incluida antes de la prueba&lt;/li&gt;
&lt;li&gt;usar siempre la m&#225;xima corriente disponible para un rango particular&lt;strong&gt;&lt;sup&gt;*&lt;/sup&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;hacer dos mediciones en dos direcciones, la segunda medici&#243;n con conexi&#243;n invertida en la entrada de VS. Calcular el promedio de las dos mediciones.&lt;/li&gt;
&lt;/ul&gt;
&lt;strong&gt;&lt;sup&gt;*&lt;/sup&gt;&lt;/strong&gt;La corriente m&#225;xima para un rango determinado depende del voltaje del suministro, longitud y secci&#243;n transversal de los cables (resistencia del cable), as&#237; como del rango de medici&#243;n m&#225;ximo en la entrada del sensor de Voltaje. El  rango de medici&#243;n m&#225;ximo en la entrada del sensor de Voltaje es de 2.5V



En caso de que el instrumento no pueda alcanzar/generar la corriente de prueba preestablecida, la pantalla mostrar&#225; el valor de la corriente m&#225;xima lograda y el resultado. Este resultado es de la precisi&#243;n m&#225;s baja, de manera que recomendamos que se repita la prueba preseleccionando el primer rango de corriente m&#225;s bajo.


&lt;h2&gt;Micr&#243;hmetros - Acerca de los cables de corriente&lt;/h2&gt;

La selecci&#243;n de los cables de corriente depende de:

 
&lt;ul&gt;&lt;li&gt;El tipo de instrumento&lt;/li&gt; 
&lt;li&gt;La amplitud de la corriente de prueba&lt;/li&gt; 
&lt;li&gt;La longitud del cable requerida para realizar la prueba&lt;/li&gt;&lt;/ul&gt;
Los &lt;a title="Micr&#243;hmetros" href="http://www.amperis.com/productos/microhmetros/"&gt;Micr&#243;hmetros&lt;/a&gt; son muy potentes y tal vez tienen la mayor potencia de salida en el mercado. Esto significa que nuestros Micr&#243;hmetros pueden generar la corriente preestablecida requerida aun con cables muy largos.


Un indicador que muestra la potencia de la salida de un instrumento es el voltaje de Carga en los contactos de la salida del instrumento con el valor de corriente requerido (FLV; &lt;em&gt;required current value&lt;/em&gt;). Por ejemplo, el instrumento puede producir:

 
&lt;table cellpadding="0" width="50%"&gt;
  &lt;tbody&gt;&lt;tr&gt;
    &lt;td&gt;&lt;strong&gt;Voltaje de Suministro&lt;/strong&gt;&lt;/td&gt;
    &lt;td&gt;&lt;strong&gt;Corriente de Salida&lt;/strong&gt;&lt;/td&gt;
    &lt;td&gt;&lt;strong&gt;Voltaje de Carga Total&lt;/strong&gt;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;230V AC&lt;/td&gt;
    &lt;td&gt;400A DC&lt;/td&gt;
    &lt;td&gt;5,0V DC&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt; 
&lt;/td&gt;
    &lt;td&gt;300A DC&lt;/td&gt;
    &lt;td&gt;6,0V DC&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;115V AC&lt;/td&gt;
    &lt;td&gt;400A DC&lt;/td&gt;
    &lt;td&gt;4,0V DC&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt; 
&lt;/td&gt;
    &lt;td&gt;300A DC&lt;/td&gt;
    &lt;td&gt;4,8V DC&lt;/td&gt;
  &lt;/tr&gt;
&lt;/tbody&gt;&lt;/table&gt;
&lt;h3&gt;a) TAMA&#209;O DEL CABLE (secci&#243;n transversal/grosor)&lt;/h3&gt;
Para seleccionar un tama&#241;o de cable, debe empezar desde la corriente de prueba requerida. Pongamos el ejemplo de una corriente de prueba de 300A y voltaje de suministro de 115V AC.


La resistencia m&#225;xima de los cables y conductores de los interruptores de circuito de energ&#237;a que se puede medir se calcula como la raz&#243;n de FLV/Corriente


4,8V/300A = 16mO


Si necesitamos cables con la longitud total de 15m (por ejemplo, 10m + 5m), entonces el tama&#241;o recomendado ser&#237;a de 35mm2. La resistencia total de los cables entonces es de 9mO. La resistencia del circuito medido (conductores  y contactos) normalmente es de alrededor de 1mO, haciendo que la resistencia del ciclo completo sea menor que el m&#225;ximo calculado.


Si necesitamos cables con la longitud total de 20m (por ejemplo, 10m + 10m o 5m + 15m) entonces el tama&#241;o recomendado ser&#237;a de 2x5m, 35mm2 + cable de extensi&#243;n de 2x5m, 50mm2. La resistencia total de los cables es de 10,2mO. La resistencia de los conductores y contactos, como se mencion&#243; antes es del orden de 1mO, haciendo que el total est&#233; dentro de los requerimientos.


&lt;strong&gt;Tabla de resistencias de cable:&lt;/strong&gt;


&lt;table cellpadding="0" width="50%"&gt;
  &lt;tbody&gt;&lt;tr&gt;
    &lt;td&gt;&lt;strong&gt;Cables de Corriente&lt;/strong&gt;&lt;/td&gt;
    &lt;td&gt;&lt;strong&gt;Resistencia&lt;/strong&gt;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x3m, 70mm2&lt;/td&gt;
    &lt;td&gt;0,9m&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x5m, 70mm2&lt;/td&gt;
    &lt;td&gt;1,5m&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x5m, 50mm2&lt;/td&gt;
    &lt;td&gt;2,1m&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x5 m, 35mm2&lt;/td&gt;
    &lt;td&gt;3,0m&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x5m, 25mm2&lt;/td&gt;
    &lt;td&gt;4,2m&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x10m, 70mm2&lt;/td&gt;
    &lt;td&gt;3,0m&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x10m, 50mm2&lt;/td&gt;
    &lt;td&gt;4,2m&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x10m, 35mm2&lt;/td&gt;
    &lt;td&gt;6,0 m&#937;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;1x10m, 25mm2&lt;/td&gt;
    &lt;td&gt;8,4 m&#937;&lt;/td&gt;
  &lt;/tr&gt;
&lt;/tbody&gt;&lt;/table&gt;
&lt;em&gt;&lt;strong&gt;Conclusi&#243;n:&lt;/strong&gt;&lt;/em&gt;

 Con base en su situaci&#243;n particular o la aplicaci&#243;n m&#225;s com&#250;n, debe calcular la  longitud y la secci&#243;n transversal de los cables que se van a usar. &lt;strong&gt;No compre cables largos y gruesos  que realmente no necesite&lt;/strong&gt;. Es probable que los cables pesen m&#225;s que el mismo instrumento dado el bajo peso inherente del instrumento aun con una salida de potencia tan alta.


&lt;h3&gt;b) TAMA&#209;O DEL CABLE - Longitud&lt;/h3&gt;
La mayor&#237;a de los clientes compra ambos cables del mismo largo, aunque uno puede ser ya sea de 3 o 5m  de largo. Es una pr&#225;ctica com&#250;n conectar un cable a un punto de tierra cercano al interruptor. El otro cable, que puede ser m&#225;s largo, se conecta al otro extremo del interruptor que se prueba y no se conecta a tierra. Nuestra experiencia demuestra que una combinaci&#243;n de un cable largo y uno corto (5m y 10m) funciona bien en la mayor parte de los casos.


En el caso de las aplicaciones con cable m&#225;s largo (de m&#225;s de 2X5m), recomendamos adquirir cables de extensi&#243;n. La combinaci&#243;n m&#225;s, com&#250;n es de 1x5m + 1x10m y se podr&#237;a lograr con cables de corriente de 2x5m + cable de extensi&#243;n de 1x5m. La combinaci&#243;n de cables de corriente de 2x5m + cables de extensi&#243;n de 2X5m puede satisfacer casi todos los requerimientos (2x10m o 1x5m + 1x15m). 
Utilizando cables de extensi&#243;n se pueden lograr varias combinaciones de longitud &#250;tiles. Es muy frecuente que sea suficiente usar s&#243;lo los cables b&#225;sicos y en esas circunstancias, se debe evitar el uso de cables largos y pesados.


Empleando cables de extensi&#243;n, es posible hacer una combinaci&#243;n en que los cables de corriente tienen la secci&#243;n transversal m&#225;s baja (es decir, 2x5m 25mm2) + cables de extensi&#243;n de 1x5m 35mm2 o 2x5m 50mm2. La resistencia de contacto entre los cables de corriente y los cables de extensi&#243;n es de menos de 100&#181;O y no influir&#237;a en la resistencia total de la corriente llevando conductores de medici&#243;n.


&lt;em&gt;&lt;strong&gt;Conclusi&#243;n:&lt;/strong&gt;&lt;/em&gt;


En lugar de largos cables pesados y complicados, &lt;strong&gt;adquiera cables de corriente b&#225;sicos (2x5m)&lt;/strong&gt;, que ofrecer&#225;n una aplicaci&#243;n ligera y sencilla la mayor parte de las veces y consiga los cables de extensi&#243;n requeridos para situaciones especiales.


</body>
    <closed-comments type="boolean"></closed-comments>
    <closed-trackbacks type="boolean"></closed-trackbacks>
    <comments-count type="integer">0</comments-count>
    <created-at type="datetime">2008-04-23T19:10:01Z</created-at>
    <date type="datetime">2008-04-23T18:59:00Z</date>
    <id type="integer">133056</id>
    <last-comment-date type="datetime"></last-comment-date>
    <myfile-id type="integer"></myfile-id>
    <nicetitle>microhmetro</nicetitle>
    <published-at type="datetime">2008-04-23T19:10:01Z</published-at>
    <site-id type="integer">1</site-id>
    <status type="integer">1</status>
    <title>Microhmetro</title>